Boiler Operator - Blue Seal Resume
|
| Desired Industry: Manufacturing |
SpiderID: 28003 |
| Desired Job Location: Clementon, New Jersey |
Date Posted: 7/30/2009 |
| Type of Position: Full-Time Permanent |
Availability Date: |
| Desired Wage: |
|
|
U.S. Work Authorization: |
| Job Level: Experienced with over 2 years experience |
Willing to Travel: Yes, 25-50% |
| Highest Degree Attained: High School/Equivalent |
Willing to Relocate: No |
Objective: I am seeking a Boiler operator or Chief Engineers posistion with the desire for long term employment, i.e., until retirement in 25 years or so.
Experience:
5 July 2005 - Present Colorite Polymers (Tekni-Plex) Engineer 609-239-2200 ext. 2218 Operate and maintained 2 Natural Gas or #6 Fuel Oil fired Superior water tube steam boilers with Economizers (1500hp) and 1 Natural Gas or #6 Fuel Oil fired Cleaver Brooks fire tube steam boiler (500hp) and associated equipment. Monitor and operate a computerized opacity meter for boilers. Operate the Compressed air system with dryers for production. Operate the Compressed air system with dryer for breathing air. Operate, repair and regenerate anion/cation mixed bed demineralizers and PLC controller for production water. Test boiler water for chemical concentrations and add necessary chemicals into chemical day tanks. On top of normal boiler house duties, I also oversee deliveries of #6 Fuel Oil, Sulfuric Acid and liquid Sodium Hydroxide. I monitor the Cooling Tower and associated pumps used for cooling of Reactors during production. Boiler House personal are also responsible for monitoring the Fire/Deluge system to ensure operation of electric and diesel fire pumps and to ensure that the fire water holding tanks are supplied with water until the fire or chemical spill is under control.
27 May 1999 ¡V 2 July 2005 Aunt Kitty¡¦s Foods Inc. (Hanover) Engineer Operated and maintained 2 Natural Gas or #3 Fuel Oil fired Cleaver Brooks water tube steam boilers (1500 & 1000hp) and associated equipment. Operated the Compressed air system with dryer for production use. Operated and maintained the Domestic Hot Water system for the plant. Tested boiler water for chemical concentrations and added necessary chemicals into chemical day tanks. Made repairs or replaced piping, valves, check valves, regulators, relief and safety valves and backflow preventers on steam, water and air systems within plant.. Installed wiring for new equipment installation and repaired or replaced damaged wiring.
23 Nov. 1992 ¡V 6 Jan. 1999 Rancocas Hospital Engineer Operated and maintained 2 Natural Gas fired Cleaver Brooks fire tube steam boilers (250 & 175hp) and associated equipment. 1 Natural Gas fired Cleaver Brooks fire tube Heating Hot Water boiler (125hp) and associated equipment. A Heating Hot Water/Steam heat exchanger and associated equipment. 1 - 250 ton and 1 - 500 ton Centrifugal Chiller and associated equipment. Operated and maintained a Domestic Hot Water system and circulating pumps. Tested boiler water for chemical concentrations and added necessary chemicals into chemical day tanks. Also performed maintenance and HVAC duties.
1 July 1997 ¡V 6 Jan. 1999 Zurbrugg Memorial Health Center Engineer Operated and maintained 3 Natural Gas or #4 Fuel Oil fired Keeler fire tube HRT boilers (350hp) and associated equipment. 1- 175 ton, 2 -50 ton and 2 ¡V 90 ton Screw Chillers and associated equipment. Operated and maintained a Domestic Hot Water system and circulating pumps. Tested boiler water for chemical concentrations and added necessary chemicals into chemical day tanks. Also performed maintenance and HVAC duties.
Education: High School Grad
Skills: ƒÞ I have fired Cleaver Brooks fire tube pack boilers, Cleaver Brooks water tube boilers, Keeler HRT boilers and Superior water tube boilers with Economizers. I am familiar with Natural Gas and #3, #4 and #6 oil firing systems. I have also performed all regular maintenance on these boilers including: Manual and Digital Control system installation including initial setup, trouble shooting and replacement of said systems, Make-up water system adjustments and repairs, Boiler water testing and chemical additions, Valve replacement, Gauge glass replacement while in operation, Electric and steam turbine pump operation, pump motor replacement and alignment, Removal and replacement of packing, New pipe instillation for steam, water and air lines, Lubrication and Clean out for inspection. ƒÞ I have operated and maintained several types of air compressors and their associated dryers for production use and air compressors and their associated dryers used for breathing air. ƒÞ I have operated, troubleshot, repaired and regenerated Anion/Cation mixed bed Demineralizers and their PLC controllers. ƒÞ I also have experience with Chillers. I have operated, maintained and repaired 50, 90, 175, 250 and 500 ton chillers as well as their pumps and their internal cooling systems. ƒÞ On top of Boiler Room duties I have also performed maintenance repairs, HVAC troubleshooting and repair, Running electrical wiring for new equipment and replacement of existing wiring.
Additional Information:
EQUIPMENT OPERATED AND MAINTAINED
Cleaver Brooks Natural Gas or #6 Fuel Oil fired, fire tube steam boilers. Cleaver Brooks Natural Gas fired, fire tube Heating Hot Water boiler. Keeler Natural Gas or #4 Fuel Oil fired, fire tube HRT boilers. Superior Natural Gas or #6 Fuel Oil fired, water tube steam boilers with Economizers. Computerized opacity meter system for boiler emissions. Steam to Heating Hot Water heat exchanger. Steam Turbine driven make-up water pumps. Electric motor driven make-up water pumps. Domestic Hot Water systems and circulating pumps. Condensate return pumps, tanks and DA tanks. Heating system for #6 Fuel Oil. Hagen control systems. Water softeners and Chemical day tanks. 50 ton and 90 ton Screw Chillers. 175 ton, 250 ton and 500 ton Centrifugal Chillers. Chiller cooling towers and pumps. Multi speed, computer controlled and adjusted chilled water circulating pumps. Vacuum pumps and receiver tanks. Heat cycled and non heat cycled, alternating air dryers. Air cooled Ingersoll ¡V Rand screw compressors. Electric motor driven Ingersoll ¡V Rand 3 piston breathing air compressors and dryer. Water cooled reciprocating Joy air compressors. Electric motor driven Elliott turbine plant air package compressor. Illco ¡VWay anion/cation mixed bed demineralizers and PLC control system. Diesel motor driven emergency generators and fire/deluge pumps. Electric motor driven fire/deluge pumps.
Reference: Available upon request.
Candidate Contact Information: