Biomedical Equipment Technician Resume
|
| Desired Industry: Healthcare |
SpiderID: 20904 |
| Desired Job Location: Drakesboro, Kentucky |
Date Posted: 5/11/2008 |
| Type of Position: Full-Time Permanent |
Availability Date: present |
| Desired Wage: |
|
|
U.S. Work Authorization: Yes |
| Job Level: New Grad/Entry Level |
Willing to Travel: Yes, Less Than 25% |
| Highest Degree Attained: Other |
Willing to Relocate: Yes |
Objective: I want to use the education, experience and skills that I have acquired for the benefit of your organization. I wish to contribute to the quality of work produced and assist in increasing the level of safety for patients and staff.
Experience: 2008 Owensboro Medical Health System Owensboro, KY Clinical Student Worked with employees to understand responsibilities of BMET I. Repaired equipment with the aid of employees and alone. Conducted scheduled preventative maintenance on equipment. Updated the equipment maintenance program (TMS). Trained other students on test equipment, PM’s and repairs. Ran Job-Fair booth at hospital for high school students.
2004-2006 Flynn Industries, Inc. Greenville, KY Assembly Line/ Piece Work Worked with fellow employees to maximize production.
Education: 1998-2002 Muhlenberg South High School Greenville, KY High School Academic Diploma. 4 year member of Physics and Astronomy Club 4 years of Spanish language
2006-2008 Madisonville Community College Madisonville, KY Associate in Applied Science Degree - Medical Equipment & Instrumentation Electronic Tester Certificate 3.94 Grade Point Average Electronic Mechanic Apprentice Certificate Certified in NIMS ICS 100 HC Certified in NIMS ICS 200 HC Electronics Technician Apprentice Certificate Member of AAMI
Skills: I am a dedicated, responsible and eager person. I am organized and I am able to prioritize. I am an amiable, calm person and can easily adapt to different situations. I have shown a solid work ethic in the classroom and in my career.
Additional Information: Clinical Experience with Equipment
Abbot Lifecare PCA + II; PCA PLUS 4100: replaced gaskets, front case (including removal and replacement of all internal components), replaced membrane touch panel, operation checks, replaced power cords, calibrated occlusion alarm springs, replaced batteries, replaced and repaired pole clamp, conducted scheduled PM
Bear Hugger: attached unit to rolling stand, inventoried
BedCheck: observed operation, replaced membrane switch
Bipolar ESU: tested output, conducted operation tests
Bladder Scanner 3000: ran service check, replaced battery, observed operation
Blanket Warmer: conducted scheduled PM
Brain Lab: Viewed equipment
Code Alert System: observed operation, conducted scheduled PM
Concha-Therm III Vent Humidifier: conducted scheduled PMs and operation and safety checks
Corometrix Infant Acoustic Stimulator: troubleshot operation, changed batteries, cleaned battery contacts
Dialysis Water Room: performed disinfection and quarterly scheduled PM
Dinamap: replaced battery, conducted scheduled PMs
Dynamometer: sent off for calibration, tested operation
Electronic Stand-on Scale: calibration, conducted scheduled PMs
Epidural Pumps: conducted scheduled PMs
Fiber Optic Surgical Light Source: replaced bulb, cleaned reflection mirror, observed operation
Flow Hood for Lab: Inventoried for cancer research labs
Flow Meter: observed oxygen flow meter replacement in open heart recovery
General Surgery Bed: viewed operation, changed ac power cord
High Frequency Digital Rad / Fleuro Room: conducted scheduled PM
Hill Rom 8500 General Patient Bed: operations check, brake cleaning and assembly, motor replacement, observed partial bed rail replacement, conducted scheduled PMs, replaced trend cable, adjusted head angle with ty-rod, replaced slide bracket, replaced wire covers
Hill Rom Advanta Patient Bed: observed operation, studied internal circuit boards and motor operation, troubleshot trend problems, replaced logic board, replaced night light bulb
Hush Slush Warming/Cooling Unit: tested operation, investigated drape burning incident
Infant Warmer: replaced defective board, rebuilt, installed, recalibrated
Kendall Sequential Compression Device (SCD): bedrail support repair, observed leak repair, battery burn in procedure, recalibrated pressure limits, replaced manifold, replaced CPU board, replaced power supply board, conducted scheduled PMs
Kendall AV-Impulse: replaced rear case and all internal components (including soldering wires into case), replaced socket face, conducted scheduled PMs
Lock Out / Tag Out Procedure: observed X-ray room preparations for repairs
Med Cart: replaced motors and fuses, verified operation
Neurological Microscope: Observed operation.
Micro Macro Plum XLD & XLM Infusion Pump: replaced mechanism assemblies, rear cases, front cases, case gaskets, doors, retainers, knob gaskets, MSU boards, internal AC connections, ac connector on power cord, battery replacements, operation and safety tests
Microtemp LT: inventoried new unit, replaced bottom case and all internal components, operation and safety checks, conducted scheduled PMs
Neopuff Infant Ventilator: observed performance of scheduled PMs
Nellcor N65 pulse oximeter: replacement of defective extension cables, replaced defective probes, battery contact repairs, conducted scheduled PMs
OB Tracevue: observed operation, log-off procedure
Olympus Endoscopy Light Source: conducted scheduled PMs
Olympus Endoscopy Video Camera: conducted scheduled PMs
Ortho-Clinical Diagnostics MTS Centrifuge: observed troubleshooting (door closure difficulty)
Patient Lift: (general patient and physical therapy) adjusted cable tension, verified operation, conducted scheduled PMs
Pevco Vacuum Tube System: observed operation
Philips Anesthesia Gas Monitor: Performed calibration
Philips Bedside Monitor & Modules: (NIBP and Pressure) tested operation, tested cable operation
Philips Heart Start XL AED Defibrillator: observed operation check
Plum III: observed operation
Plum A+ Infusion Pump: changed battery, observed operation
Plum A+ Triple Infusion Pump: observed operation
Security Camera: assisted with installation in psychiatric ward, verified operation
Siemens X-Ray Room: involved in troubleshooting arc, requisitioned inverter from Part source, filled out PO, replaced inverter with electrolytic gel leak with assistance from other student, assisted with replacement of brake shoes, replaced x-ray tube, performed calibration, adjusted collimator, replaced brake, calibrated brake pins to engage at correct time, observed chest stand correction
Site Rite Ultrasound: Assembled unit, tested printer
Steris System I Processor: (Endoscope Sterilizer) conducted scheduled PM, changed 3 check valves, air filter, and air pinch-off valves
Surgery Overhead Lights: observed bulb replacement procedure
TEE Probe: (Trans Esophageal Echocardiogram Probe) sent in for repair
Telemetry Pack: entered packs into system, changed battery doors, reseated cables, installed printer, conducted operation test with simulator
Therapeutic Ultrasound: (Exeltech, and Intellect 700C) conducted scheduled PMs, observed operation
Total Care Sport Patient Bed: replaced stepper motors, disassembled and reassembled patient side-rail, troubleshot operational noise, observed operation
Total Management System: (TMS) Entered Passed/Failed PMs, Repairs, New equipment, Retired equipment, new PM schedule, vendor repairs, etc…
Ultrasound: replaced (Philips) monitor and verified operation
UPS: (uninterruptible power supply) replacement of battery and operation test
Vacuum Suction Pump for Endoscopy: conducted scheduled PMs
840 Ventilator: performed extended service test
Verian Trilogy: Viewed equipment and room
Welch-Allyn 420 Spot NIBP: replaced front case, conducted scheduled PM
***Additional BMET Experiences*** Trained other students on PM routines, repairs, and test equipment usage, Participated in job fair booth at hospital for high school students, Sat in on a monthly Biomed meeting, Requisitioned parts, Inventoried new equipment, Used grounding mat for repairs, Filled out POs and took them to Facilities office, Placed orders with manufacturers, Returned defective parts, Retired equipment from service, Sent equipment to manufacturer for repair, Assisted with request for service contract, Soldering, Service runs throughout hospital to retrieve and replace broken equipment, Developed an awareness for occasional weekend work (PM of dialysis water room).
***Simulators and Meters Experience*** Electrical Safety Analyzer, Sim Cube, Smart Arm, Fluke Multimeter, Victoreen Rad Meter, Ultrasound Watt meter, Telemetry Simulator, Fluke Pressure Meter, ESU Output Meter, Bed Controls Operation Analyzer, Defibrillator Analyzer, Temperature Meter, Thermometer Analyzer
Reference: College: Medical Equipment and Instrumentation Program Coordinator Madisonville Community College NAME: Joey Jones CERTIFICATIONS: CBET WORK PHONE: (270) 824-1759 EMAIL ADDRESS: joey.jones@kctcs.edu Attn: Joey Jones Technology Campus 150 School Ave. Madisonville, KY 42431
Clinical Site: Clinical Supervisor Owensboro Medical Health System NAME: Daniel Clark POSITION: BMET 2 AAS WORK PHONE: (270) 688-2728 EMAIL ADDRESS: dclark@omhs.org Attn: Dan Clark Biomed 811 East Parrish Ave. Owensboro, KY 42303
Clinical Advisor Owensboro Medical Health System NAME: Kyle Dailey POSITION: BMET 2 WORK PHONE: (270) 688-3277 EMAIL ADDRESS: daileyk@omhs.org Attn: Kyle Dailey Biomed 811 East Parrish Ave. Owensboro, KY 42303
Clinical Advisor Owensboro Medical Health System NAME: Joseph Walker POSITION: BMET 2 AAS WORK PHONE: (270) 688-1940 EMAIL ADDRESS: jwalker@omhs.org Attn: Joseph Walker Biomed 811 East Parrish Ave. Owensboro, KY 42303
Personal: Work Associate Flynn Corporation NAME: Susan Bailey JOB TITLE: Surgical Technician PHONE: (270) 543-4817 EMAIL ADDRESS: thebaileys591@bellsouth.net
Long-Time Friend NAME: Vanessa Rolley JOB TITLE: Respiratory Therapist PHONE: (270) 476-7471 EMAIL ADDRESS: vandanrolley@netscape.com